Verification · Certificates issued

Certificate AN-2026-00012

Valid

Issued

This certificate was issued by ANALYTON and has not been withdrawn.

Verification confirms that a certificate with this number and key was issued by ANALYTON on the date shown, for the sample described, and states its current status.

Download the certificate (PDF)

Record
Report numberAN-2026-00012
Issued2026-09-22
StatusValid
SampleCJC-1295 no DAC + Ipamorelin, lyophilised powder, vial labelled 10 mg (5 mg + 5 mg)
Batch numberATCJI-10-2509-01
MatrixResearch peptide
Determinations performed19
Issued byANALYTON
Certificate fileAN-2026-00012.pdf
01Results 19
As reported on certificate AN-2026-00012
Determination Method Result Specification
Appearance Visual White to off-white powder White to off-white powder
Purity RP-HPLC, C18, 214 nm (280 nm control trace), area % 99.25 ± 0.20 % (k = 2) >= 98.0 %
Related substances RP-HPLC, 214 nm; LOD 0.01 %, LOQ 0.03 %, reporting threshold 0.05 % Largest single impurity 0.53 % at RRT 0.96 (± 0.03 %); total impurities 0.75 % Single <= 1.0 %, total <= 2.0 %
Impurity profile RP-HPLC with LC-HRMS assignment RRT 0.96, 0.53 %, same mass (isoAsp, 2x Asp in sequence); RRT 1.03, 0.09 %, +0.98 Da (deamidation of Gln/Asn); RRT 1.06, 0.13 %, -18.01 Da (Asp succinimide) Peaks above 0.05 % reported (ICH Q3B)
Net peptide content Assay 85.03 ± 1.2 % w/w (k = 2), CJC-1295 no DAC only —
Fill weight Gravimetric 10.40 ± 0.05 mg Labelled 10 mg
Vial-to-vial consistency Gravimetric, two vials of the batch 10.40 and 10.66 mg, difference 2.5 %; purity of both within 0.1 % <= 5 %
Counter-ion content Ion chromatography, suppressed conductivity Acetate 6.65 % w/w (± 0.40 %), CJC-1295 no DAC only —
Trifluoroacetate Ion chromatography, LOQ 20 ppm Not detected, CJC-1295 no DAC only —
Water content Coulometric Karl Fischer, USP <921> 7.67 ± 0.38 % w/w (k = 2), i.e. 0.80 mg per vial —
pH Potentiometric, 10 mg/ml in water 5.2 4.4 to 6.0
Solubility Visual, 10 mg/ml and 1 mg/ml >= 10 mg/ml in water and in bacteriostatic water; clear, colourless, free of particles within 30 s Clear solution
Bacterial endotoxins Kinetic chromogenic LAL, USP <85> < 0.05 EU/mg (< 0.52 EU per vial) <= 10 EU/mg
Sterility Membrane filtration, USP <71>; fluid thioglycollate 30 to 35 °C and soya bean casein digest 20 to 25 °C No growth after 14 days, 2 vials No growth
Microbial enumeration Plate method, USP <61> and <62> TAMC < 10 CFU/g, TYMC < 10 CFU/g; E. coli, Salmonella, S. aureus and P. aeruginosa absent in 1 g TAMC <= 1000 CFU/g, TYMC <= 100 CFU/g, specified organisms absent
Residual solvents Headspace GC, USP <467> Acetonitrile 45 ppm; N,N-dimethylformamide, methanol, dichloromethane, diethyl ether, diisopropyl ether and piperidine each < 10 ppm (LOQ 10 ppm) ICH Q3C: acetonitrile <= 410, DMF <= 880, methanol <= 3000, dichloromethane <= 600, ethers <= 5000 ppm
Elemental impurities ICP-MS after microwave digestion (HNO3/H2O2), USP <233> Cd, Pb, As, Hg < 0.05 µg/g; Co, V, Ni < 0.10 µg/g, all below LOQ ICH Q3D(R2) Class 1 and 2A, parenteral PDE
Chiral purity (D-amino acids) Acid hydrolysis (6 M DCl in D2O, 110 °C, 24 h), Marfey's derivatisation (FDAA), LC-MS D-Asp 0.12 %, D-His 0.10 %, D-Ser 0.08 %, D-Phe 0.06 %, D-Tyr 0.05 %, D-Thr 0.05 %, D-Gln 0.05 %, others < 0.05 %; intended D-2-Nal, D-Phe, D-Ala >= 99.5 % D; Aib achiral; sum of D-forms 0.63 % Each D-amino acid <= 0.2 %, sum of D-forms <= 0.5 %
Compound screening LC-HRMS full scan, m/z 100 to 2000, against library: fentanyl and analogues, CJC-1295 with DAC, GHRP-2, GHRP-6, sermorelin, protected intermediates (tBu, Boc, Trt, Pbf, Fmoc), free amino acids None detected above 0.05 % area No foreign compound above 0.05 % area
02The sample and the run
Controls carried in the same sequence
BlankSolvent blank (mobile phase A) injected before the sequence; no peak above 0.02 % of the main peak within RRT 0.80 to 1.30
Reference standardIn-house reference standard RS-IPA-01 (purity assigned against a primary standard, stored at -20 °C) injected at the start and end of the sequence; area difference 0.4 %, retention time within 0.1 min
03Check your copy of the file

This is the SHA-256 of the certificate file exactly as it was issued. Run the command against the file you were sent: if the two strings match, your copy is byte for byte the one this laboratory issued.

A copy that has been re-saved, printed to a new file or passed through a converter will not match, because each of those produces a different file. Compare the certificate exactly as it was sent to you, or the copy downloadable from this page.

84b6fd2eaf757e62f7aee3e86052c5430dddef3bde1fafc8ae667f4bc4787c16

shasum -a 256 AN-2026-00012.pdf

On Windows: certutil -hashfile AN-2026-00012.pdf SHA256

04Show this result elsewhere

This badge links to this record, so anyone who clicks it lands on the laboratory's own copy of the result.

The same record is available as JSON at /verify/AN-2026-00012-PP5EWM9SSS/record.json, so a shop can pull the results into a product page without anyone retyping a number.

Tested by ANALYTON, report AN-2026-00012

<a href="https://analyton.com/verify/AN-2026-00012-PP5EWM9SSS/"><img src="https://analyton.com/verify/AN-2026-00012-PP5EWM9SSS/badge.svg" alt="Tested by ANALYTON, report AN-2026-00012" width="260" height="70"></a>

Verified against the ANALYTON register. Questions to lab@analyton.com